Kantronics KPC 3 Plus Commands
(You will need to enter the following commands after a hard reset)

19 COMMANDS - Version 9.1
COMMENTS
INTFACE 
TERMINAL

MY 
V?7???
 Enter your Callsign
MYR 
V?7???-9
 Remote control Callsign-9
NETC 
V?7???-8
 K-Net Callsign and SSID
MYA 
DISABL
Disable not required
MYN 
DISABL
Disable not required
CD 
SOFTWARE

DIGI 
OFF
 We use Nodes vs digipeating (more efficent)
FRACK 
3

MYPPBS 
DISABL
Disable not required
NDWILD 
OFF
 OFF not required we use K-Net Node
NETA 
497???
 NETALIAS - referance freq/suffix of Callsign
NUMNODES 
0
 0, we use K-Net Nodesvs KA Nodes
PBBS 
0
 0, We do not use personal mailbox
RETRY 
5

RTEXT 
??????????
 This is the password for the remote Callsign
TRIES 
5

USERS 
5

XMITL
???
 XMITL numbers = Deviation level of 2.75 KHz